JKWA series Reactive power automatic compensation controller has high measuring precision,is suitable for three-phase balanced load compensation system,Easy installation and operation.The controller has the functions of real-time monitoring of the grid parameters, harmonic protection, reactive power compensation and fault warning.
Voltage,current,fact,active power,reactive power , frequency,THDi ,THDu, working status,alarm.
Over voltage,under voltage,high harmonic rate protection and alarm
Outputs will be Auto reset,when power on system
Auto lock when sample current is below 0.1A
Data protection after power off
型號 |
補償方式 |
基本參數測量 |
保護功能 |
輸出路數/接點 |
適配投切開關 |
通訊接口及方式 |
JKWA-12E/12FD |
三相共補
|
電壓/電流/功率因數/有功/無功功率等;電容器投切狀態;電壓總諧波畸變率、電流總諧波畸變率,系統頻率
|
過壓保護 欠壓保護 諧波保護 |
12路 有源接點 DC12V 60mA/路
|
抗諧波開關 調節器開關 復合開關 可控硅模塊
|
無 |
JKWA-12EJ |
三相共補
|
電壓/電流/功率因數/有功/無功功率等;電容器投切狀態;電壓總諧波畸變率、電流總諧波畸變率,系統頻率
|
過壓保護 欠壓保護 諧波保護 |
12路 干接點 AC220V,5A/路
|
交流接觸器 |
無 |