    JKWF Hybrid reactive power compensation controller
    JKWF series Hybrid reactive power compensation controller integrates the functions of Monitoring grid ,harmonic protection, compensation and fault warning...
    YBYKXB Resist harmonic intelligence switch
    YBYKXB Anti harmonic intelligent switch is Application of advanced compensation measurement and control technology,All electronic, intelligent, high performance dynamic compensation switch....
    YBYCRz Capacitors
    YBYCRz series cylinder type self-healing low voltage power capacitor,use German treofan material, with the most advanced manufacturing processes and equipment produced....
    Quality assurance of power quality components
    Rigorous, precise quality inspection is the focus of the work of AIA Yi, from the beginning of the screening test material to assembly line inspection, installation testing, etc. process through the digital monitoring strictly, each process into products...
    YBYFCP優(yōu)電節(jié)能裝置
    以電力電子技術(shù)為核心,以全面解決電能質(zhì)量問題,提高供電可靠性為目標(biāo)的多功能裝置...
    Quality assurance of compensation filter unit
    Harmonic generator for real simulation, using harmonic source and three level test bench to ensure product quality, and strive to bring customers safe, high-quality products...
    有源電力濾波器YBYAPF
    采用了一種全新的全數(shù)字化PWM電流跟蹤控制算法,確保設(shè)備有極高的電流跟蹤精度,從而實(shí)現(xiàn)優(yōu)秀的補(bǔ)償效果...
    Quality assurance of active module
    Harmonic generator for real simulation, using harmonic source and three level test bench to ensure product quality, and strive to bring customers safe, high-quality products...
    YBYTU800 Harmonic monitor
    The product integrates data collection, statistics, communications, power grid harmonic analysis, harmonic alarm and other functions....
    Quality assurance of harmonic monitoring platform
    Rigorous, precise quality inspection is the focus of the work of AIA Yi, from the beginning of the screening test material to assembly line inspection, installation testing, etc. process through the digital monitoring strictly, each process into products...
  • Cases
    The power distribution system of drilling platform has been powered by generators, and has been powered by electricity. Now, the power supply is provided by the power grid. Because of the large amount of harmonic currents generated by DC motor and frequency conversion motor, dynamic reactive power compensation and harmonic control are needed. The frequent start and stop of the motor causes great interference to the power grid
    The main load equipment is the frequency converter. Because of the large harmonic current (especially the 5 and 7 harmonics) produced by the load, the voltage and current of the system will be distorted, which will affect the normal operation and safety production of the equipment. The input side of the inverter is a nonlinear rectifier circuit, which affects the waveform of the power supply. The output side voltage, current, non sinusoidal or incomplete sine wave are rich in harmonics.
    Container terminal loads are mostly cranes, which are impulse loads, with large amplitude and obvious voltage drop. Especially during the whole process, flickering and voltage collapse are very obvious. The power factor of the motor is very low during starting up. This impulse reactive power will make the grid voltage fluctuate violently, even even the users connected to the same power grid can not work normally.
    In the port industry, the loading and unloading bridges and the belt conveyer are widely adopted by AC frequency converter and DC rectifier. This kind of load is a typical nonlinear load...
    Through the effective protection of the harmonic control after the safe use of transformers, power distribution cabinets, and equipment, prolong the service life of the equipment; the utility grid device to produce additional power consumption is reduced; improve the efficiency of electricity charging equipment, battery charging protection in the process of safety; greatly reduces the harmonic current into the power grid, to avoid the interference of adjacent power supply system.
    After the active filter is put into operation, the total current distortion rate is reduced to 0.75%. The quality of the power grid has been greatly improved, which effectively protects the normal operation of the equipment.
    The total current distortion rate is reduced to 4.78%, the distortion rate of each subharmonic is within 1.5%, and the waveform of the non sinusoidal wave before the treatment is a sine wave. It can be seen that after the input of the filter, the harmonic of the system has been well suppressed, improving the reliability of the power supply system, eliminating the hidden trouble of the influence of the system harmonic on the communication system, and receiving good results.
  • Service support
    we will take any of your needs and consultations seriously and welcome you to contact us......
    Professional engineers provide comprehensive and systematic technical training and operation guidance for customers, including fault diagnosis, equipment commissioning, equipment maintenance, product selection, and overall solution, to meet diverse needs of different types of customers.
    In order to solve your technical problems more quickly, please consult the acquisition support - common question answer FAQ content....
    To understand the more comprehensive electrical products and model parameters of YBY electric, welcome to download the album of related products.....
    Download the product certificate from YBY electric, product patent certificate, 3C certification, CQC and other certificates…....
    YBY provides professional product knowledge and solutions to help enterprises cultivate professional talents, improve the overall technical ability, and actively assist the continuous development of enterprises.......
    Related products and services, the company according to your actual needs in twenty-four hours or an agreed time to provide on-site technical service personnel. As required, please try to provide detailed information so that we can better serve you.
    the company according to your actual needs in twenty-four hours or an agreed time to provide on-site technical service personnel. please try to provide detailed information so that we can better serve you.
    When you have any comments and suggestions about our products, packaging, transportation and customer service service, can be put to us, we will be the first time response, give you a professional, efficient and satisfactory service. As required, please try to provide detailed information so that we can better serve you.
    Related products and services, the company according to your actual needs in twenty-four hours or an agreed time to provide on-site technical service personnel. As required, please try to provide detailed information so that we can better serve you.
  • Partner
  • About us
Login
CASES

Communication base station

Status Analysis:

      In the communication room, switching power supply and UPS have become indispensable devices in the computer room, which can provide high quality voltage with high voltage stability, stable frequency and small waveform distortion to the load, and can provide power supply without interruption during static bypass switching. However, due to the switching power supply and UPS are nonlinear loads, they at the same time ensure the output high precision power of its own and will produce a large number of harmonic current at the input end, harmonic pollution to the power grid, also affect the room of other sensitive equipment, increase operation loss of the communication system of transformer, cable, busbar and other equipment, the diesel generator, transformer, power cable, power electronic equipment, low-voltage capacitor equipment damage, reduce the safety and reliability of distribution system. Therefore, the communication machine room must face the problem of harmonic control. The main load for UPS power supply, air conditioning, server; power quality exceed the standard project for the harmonic current; A phase current effective value of 222 ampere current harmonic distortion rate is 32.6%; B value of current 203 amperes, current harmonic distortion rate is 31%; C value of current 230 amperes, the total current harmonic distortion rate 35.6%.

Governance measures:

      According to the site conditions and the measured results, the main harmonic produced by DC power supply UPS and some nonlinear, solve the harmonic perfect set in accordance with the scheme, the compensation capacity of our company for shunt active power filter 100A, automatic tracking control of load harmonic current is generated, to ensure safe and reliable operation of the whole system.


The effect of Governance:

The total current distortion rate is reduced to 4.78%, the distortion rate of each subharmonic is within 1.5%, and the waveform of the non sinusoidal wave before the treatment is a sine wave. It can be seen that after the input of the filter, the harmonic of the system has been well suppressed, improving the reliability of the power supply system, eliminating the hidden trouble of the influence of the system harmonic on the communication system, and receiving good results.
1, the main load of intermediate frequency furnace, the six phase rectifier bridge is a typical harmonic source.
2. Due to the overload operation of the transformer, the voltage distortion is caused, and the harmonics are also greatly increased.
Change control 3, six phase rectifier makes the thyristor current in the process of phase change tube rate greatly, the load waveform presents a right angle change rate, wave coefficient is poor, harmonic distortion.
4. When the power factor can not meet the requirement, it is only due to the poor wave coefficient, so the conventional reactive power compensation equipment can not be compensated.
5. When the medium frequency furnace runs at full load, the total current distortion rate is 22.5%, and the main harmonic current is 5 times, 7 times, 11 times and 13 times.
6. The effective value of the single phase current is 761 amperes.







Return
Interested in Our Service? /Support Hotline:400-655-6668 Solution Requirements Sheet
0755-895848730755-89584873
E-mailliuxw@china-yby.com
Online InquiryOnline Inquiry
Wechat
主站蜘蛛池模板: 国产欧美日韩精品一区二区三区 | 窝窝人体色www | 把女的下面扒开添视频 | 久久久久国产亚洲日本 | 超碰超碰在线观看 | 国产久免费热高清视频在线观看 | 色se02短视频永久网站 | 欧美疯狂做受xxxx | 国语国产精精品国产国语清晰对话 | 我真的不是气运之子动漫免费观看 | 日韩国产一级片 | 久久青青草原一区二区 | 免费观看黄页网站 | 斗罗大陆3龙王传说第四季免费观看 | 欧美肉大捧一进一出免费视频 | 四虎影视免费在线 | ASSFREE疯狂老妇熟女 | 免费观看又色又爽又黄的校园 | 伊人91| 手机免费av在线 | 国产在线精品无码不卡手机免费 | 日本欧美一区二区三区视频麻豆 | 亚洲欧美天堂在线 | 精品日产一区二区三区手机 | 藏精阁成人免费观看在线视频 | 人牛交VIDE欧美XXXX | 亚洲日韩一区精品射精 | 亚洲国产精品久久久久 | av片播放| 日韩毛片网站 | 亚洲中文成人中文字幕 | 四虎影视在线影院在线观看 | 国产又粗又硬又猛的毛片视频 | 亚洲精品成人福利网站 | 第一页av| 国产精品久久久不卡 | free性欧美1819护士 | 一级片精品| 久久w5ww成w人免费 | 又黄又爽又刺激的视频 | 日韩亚洲欧美在线 |